Introducing the new phase lock accessory for the UltraTEV Plus², helping you record accurate PRPD patterns in the field.
A handheld measurement device and a connected sensor, used for testing purposes.
EA Technology

EA Technology, specialist in asset management solutions for owners and operators of electrical assets, has launched an innovative new accessory for its UltraTEV Plus² instrument for partial discharge (PD) detection.

The new Wireless Phase Reference (WPR) unit makes PD data analysis easier and more accurate by helping to ensure a high-quality phase lock. Now available in the Americas market.

Portable moisture meter and calibration device on a white background.

The compact and robust WPR unit connects to the UltraTEV Plus² via Wi-Fi. It offers a reliable and versatile method for providing a phase lock to match the frequency of the test instrument to the 50 or 60Hz frequency of the HV network. This allows PD events to be plotted on a phase resolved partial discharge (PRPD) display, to allow patterns to be interpreted on the first attempt at surveying, ensuring effective time management of staff.

A high quality phase lock is essential to be able to differentiate between PD and noise, as well as to enable discharges on different phases to be detected.

EA Technology has put customers at the forefront, considering feedback that the most common methods of generating phase locks were often unreliable and inconsistent, sometimes due to substation layout, or to accidental user error. The newly developed WPR emits a wireless signal once it has connected to a phase lock and can be easily maintained throughout a substation survey.

The advantage of the WPR accessory is that as a separate unit from the handheld instrument, it is unaffected by the actions of the user. For example, accidental blocking or shading of the UltraTEV Plus² on-board photosensor.

Graph showing scattered data points labeled as "Data without Phase Lock" in a workshop setting.

Scatter plot showing data points with phase lock, highlighting identifiable partial discharge (PD) events.

David Russell, HV Project Manager at EA Technology said: “With our award-winning UltraTEV range we strive to help customers achieve more effective and accurate detection. The introduction of the Wireless Phase Reference accessory for the UltraTEV Plus² is the latest part of this commitment and the result of listening to feedback from customers.”

Watch a short video from our Australia office explaining the frequency phase lock and its importance below (plays on a new tab):

Text on a purple background discussing Phase Locking for PD testing by EA Technology.

Free Guide
The growing gap between energy awareness and demand

The whitepaper explores the growing gap between consumers’ efforts to reduce energy use and rising electricity demand, highlighting why smarter, more visible and flexible LV networks are essential as EVs, heat pumps and distributed energy resources accelerate electrification.

Download here
Consumer Energy Trends Whitepaper
Consumer Energy Trends whitepaper cover