Different assets need different sensors. Extend your partial discharge detection capabilities with our range of probes, antennas and contact sensors to survey cables, overhead lines and enclosed switchgear with a single instrument.
Wireless Phase Reference
Provides a reliable wireless phase reference, so partial discharge activity can be plotted against the power cycle first time.
UHF Directional Antenna
Picks up airborne UHF emissions across a substation, helping you narrow down where partial discharge is coming from.
UltraDish
Parabolic ultrasonic dish for detecting surface discharge and corona at a distance on outdoor and overhead assets.
UHF Barrier Spacer Sensor
Detects partial discharge in EHV and HV gas insulated switchgear by reading through the insulating barrier spacers.
UHF Receiver
Extends UHF detection into enclosed and gas insulated switchgear, where TEV and ultrasonic methods reach their limits.
UltraTEV Plus² Locator Probe
Narrows a TEV reading down to the individual panel or compartment generating the discharge.
HFCT Sensor Kit
Clamps around cable earth straps to capture partial discharge activity travelling along high voltage cables.
Ultrasonic Contact Probe
Reads ultrasonic discharge through the metalwork of sealed chambers, where there is no air path to the source.
Ultrasonic Flexi-Sensor
A flexible probe for reaching ultrasonic emissions in confined or awkward spaces inside switchgear.
Voltage Presence Indicating System (VPIS)
Connects to the switchgear's existing voltage indicating system to detect partial discharge in MV switchgear and cables.
UltraBolt
A switchgear bolt with a built-in ultrasonic sensor, giving a fixed reference point for faster, more consistent PD testing.
Not sure which accessory you need?
Every asset type and environment calls for a different detection method. Our partial discharge specialists can help you match the right sensors to your switchgear, cables and overhead lines, and build a kit around the surveys you actually carry out.
Latest Insights
Technical insight, research and commentary from across our engineering and consultancy teams.
)
Partial Discharge Monitoring: Extending asset life without the guesswork
When the life of an asset is now set by policy rather than design, the condition data build in at the acquire stage could decide its options later.
)
Age of electrification exposing Australia’s weakest link
Australia has spent more than a decade transforming its energy supply, with renewable energy in the National Electricity Market growing from 15% in 2015 to a record 46.5% in 2026.
)
Australia’s Budget Highlights LV Visibility Gap for DNSPs
Australia’s 2026–27 Federal Budget highlights the growing need for low-voltage network visibility as EV adoption rises and DNSPs prepare for electrification.
)